OFFICE (417) 869-6474
FAX NUMBER: (417) 862-0968
OPERATION AND
MAINTENANCE
MANUAL
AIR HANDLING
UNITS
ALL REQUESTS FOR FACTORY ASSISTANCE
MUST BE ACCOMPANIED BY THE SPECIFIC
UNITS SERIAL NUMBER.
Page view 0
1 2 3 4 5 6 ... 16 17

Summary of Contents

Page 1 - UNIT’S SERIAL NUMBER

CUSTOMER SERVICE DEPARTMENT OFFICE (417) 869-6474 FAX NUMBER: (417) 862-0968 OPERATION AND MAINTENANCE MANUAL AIR HANDLING UNITS

Page 2 - Table of Contents

C-90 FOR 6" RIGID FILTER WITHOUT HEADER AIR C-99 FOR 12" RIGID FILTER WITHOUT HEADER AIR AIR UPSTREAM

Page 3

AIR C-79-1 (2" Pre Filter) C-79-2 (4" Pre Filter) FINAL FILTER PRE FILTER AIR Figure 8 C-79-1 &

Page 4 - (Standard)

4.0 Blowers See the product specific I, O&M. 5.0 Air Balance Velocity - When air moves at a given velocity in a duct, it creates a pressure c

Page 5

velocity energy is lost as a result of the design of the duct where the area changes. Some of the velocity energy is converted into static pressure e

Page 6 - C-70 Filter Clip Application

5.7 Magnahelic Pressure Gauge (Standard) "Magnahelic" is not a generic term but is registered by Dwyer Instrument Company. The magnahelic

Page 7 - C-86 Filter Clip Application

6.4 Piping & Control Consult the job specification for the specific piping requirements for each unit. 6.5 Condensate Drain The majority of

Page 8 - C-89 Filter Clip Application

7.0 Dampers With the custom design nature of the Loren Cook equipment, your unit may contain outside air, supply air, return air, exhaust air, face

Page 9 - C-77 Filter Clip Application

Limited Warranty Loren Cook Company warrants that your Loren Cook fan was manufactured free of defects in materials and workmanship, to the extent st

Page 10 - DOWNSTREAM ACCESS

Table of Contents Section 1.0 1.1 General Receiving the Equipment 1.2 Shipped Loose Parts 1.3 Visual Inspection of Equipment Section 2.0

Page 11 - C-79 Filter Clip Application

1.0 General This manual has been prepared as a guide for installing, operating and maintaining Loren Cook heating and cooling equipment. Due to

Page 12

2.2 Long-Term Storage Long-term storage is considered to be any period longer than six (6) months from date of shipment. If long-term storage i

Page 13

3.3 Filter / Holding Frame / Clip Application Guide Pre filter Pleated/Panel/ Rigid/Bag/Filter Filter Clip # of Clips per Filter Filter Access Page

Page 14 - (Summer Conditions)

AIR Figure 4 Figure 1 C-70 Clip location for 6" & 12"Rigid & Bag filters with peripheral he

Page 15

AIR AIR AIR AIR Figure 6 Figure 2 C-86 Clip location for 6" & 12" Rigid & Bag filters with per

Page 16

AIR AIR Figure 6 C-89 Clip location for 6" & 12" Rigid & Bag filters with peripheral header &am

Page 17 - LOREN COOK COMPANY

AIR AIR Figure 3 C-77 Clip location for 4" filter for downstream access C-77 Filter Clip Applicati